IMPORTANT INFORMATION
IMPORTANT INFORMATION IMPORTANT INFORMATION
IMPORTANT INFORMATION
KEEP FOR OPERATOR
KEEP FOR OPERATOR KEEP FOR OPERATOR
KEEP FOR OPERATOR
IMPORTANT INFORMATION
IMPORTANT INFORMATION IMPORTANT INFORMATION
IMPORTANT INFORMATION
OPERATOR MANUAL OM-HY-5G
Part Number 138486 Rev B DOMESTIC
MODELS: HY-5G, (2)HY-5G
HyPerSteam™
Atmospheric Convection
Steamer
Self-Contained
Gas Heated
Capacity: 5 Steamer Pans [per cavity] (HY-5G)
(12" x 20" x 2½”)
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ,
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS
CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE
.
POST IN A PROMINENT LOCATION
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT USER SMELLS GAS. THIS
I
NFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS
SUPPLIER. AS A MINIMUM, TURN OFF GAS AND CALL YOUR GAS
COMPANY AND YOUR AUTHORIZED SERVICE AGENT. EVACUATE ALL
PERSONNEL FROM THE AREA.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH.
READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
HY-5G
(2)HY-5GF
OPERATOR MANUAL
Part Number 142113 Rev D
IMPORTANT INFORMATION I KEEP FOR OPERATOR I IMPORTANT INFORMATION
®
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - OPERATOR MANUAL

•••••••• IMPORTANT INFORMATION IMPORTANT INFORMATION IMPORTANT INFORMATION IMPORTANT INFORMATION •••• KEEP FOR OPERATOR KEEP FOR OPERATOR KEEP

Seite 2

OM-HY-5G10OM-HY-5G10OperationWARNINGANY POTENTIAL USER OF THE EQUIPMENT MUST BE TRAINED IN SAFE AND CORRECT OPERATINGPROCEDURES.A. ControlsOperator co

Seite 3 - References

OM-HY-5G11OM-HY-5G11The timer is used in three ways:1 In the OFF position the steam generatorstays at a low boil or “holding” temperature.2 When a coo

Seite 4 - Inspection and Unpacking

OM-HY-5G12OM-HY-5G12CleaningTo keep your HY-5G Steamer in proper working condition, use the following procedure to clean the unit. Thisregular cleani

Seite 5 - Water Quality and Treatment

OM-HY-5G13OM-HY-5G13Steam Generator and Cooking ChamberOn a regularly scheduled basis, or if the SERVICElight is on, follow the simple de-liming instr

Seite 6 - Installation and Start-Up

OM-HY-5G14OM-HY-5G14MaintenanceThe HY-5G Steamer is designed for minimummaintenance, and no user adjustments should benecessary. Certain parts may ne

Seite 7

OM-HY-5G15OM-HY-5G15Parts List - HY-5GTo order parts, contact your authorized Groen Service Agency. Supply the model designation, serial number, part

Seite 8

OM-HY-5G16OM-HY-5G16Parts List - (2) HY-5GTo order parts, contact your authorized Groen Service Agency. Supply the model designation, serial number,

Seite 9 - Initial Start-Up

OM-HY-5G17OM-HY-5G17 Electrical Parts List - HY-5GTo order parts, contact your authorized Groen Service Agency. Supply the model designation, serial

Seite 10 - Operation

OM-HY-5G18OM-HY-5G18Parts List - HY-5GTo order parts, contact your authorized Groen Service Agency. Supply the model designation, serial number, part

Seite 11

OM-HY-5G19OM-HY-5G19Electrical Schematic - HY-5GAll VoltagesHY-5G Wiring DiagramP/N 130396 Rev A

Seite 12 - Cleaning

OM-HY-5G2IMPORTANT — READ FIRST — IMPORTANTWARNING: THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITYAND PLUMBING. IMPROPER I

Seite 13

OM-HY-5G20OM-HY-5G20Service LogModel No. Serial No.

Seite 14 - Troubleshooting

OM-HY-5G21OM-HY-5G20Service LogModel No. Serial No.

Seite 15 - Parts List - HY-5G

OM-HY-5G22OM-HY-5G22LIMITED WARRANTY TOCOMMERCIAL PURCHASERS*(U.S. & Canadian Sales Only.)Groen warrants to original commercial purchaser/users th

Seite 16 - Parts List - (2) HY-5G

OM-HY-5G23OM-HY-5G23VII. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED ORIMPLIED, INCLUDING ANY IMPLIED WARRANTY

Seite 17

OM-HY-5GPart Number 142113 Rev. D1055 Mendell Davis DriveJackson, MS 39272Telephone 601 372-3903Fax 601 373-9587unifiedbrands.net

Seite 18

OM-HY-5G3OM-HY-5G3Table of ContentsOPERATOR WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 19 - All Voltages

OM-HY-5G4OM-HY-5G4Equipment DescriptionYour Groen HY-5G or (2)HY-5G HyPerSteamConvection Steamer is designed to give years ofservice. It has a stainle

Seite 20 - Service Log

OM-HY-5G5OM-HY-5G5(2)HY-5GFThe second water connection can reduce treatedwater requirements.Water Quality and TreatmentHY-5GIt is essential to supply

Seite 21

OM-HY-5G6OM-HY-5G6Installation and Start-UpWARNINGTHE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH GAS,ELECTRICITY

Seite 22 - COMMERCIAL PURCHASERS*

OM-HY-5G7OM-HY-5G7After the unit has been connected to the gassupply, all gas joints must be checked for leaks.No flame should be used when checking f

Seite 23

OM-HY-5G8OM-HY-5G8D. Drain ConnectionSteamers must be leveled front to back, orpitched to the rear (maximum ¼ inch) byadjusting the bullet feet on the

Seite 24

OM-HY-5G9OM-HY-5G9Initial Start-UpAfter the HY-5G Steamer has been installed, test itto ensure that the unit is operating correctly.1. Remove all lite