To lower temperature in the refrigerated rail:
A. Push and hold the set button until 34 appears and then relea se th e
“set” button. 34 is the current set point temperature.
B. Push and release the up a rrow 2 times until 32 is d ispla yed. Push a nd
release the set” bu tton one time. The new set point, 32, will flash 3
times and then will be locked in.
NOTE: It is recommended to only make changes of 2 degree increments
at a time. Allow for the unit to operate 24 hours between adjustments. If
the 2 degree adjustment is not enough another adjustment can be made.
The maximum highest setting is 38 degrees and the minimum lowest
setting is 28 degrees. If the settings need to go above or below this point
there may be other contributing factors as to the cause of the
temperature variances, please contact the factory at 1-800-621-8560.
The base temperature can also be adjusted by the temperature control dial located
on the front of the refrigeration coil inside the refrigerated base. The thermometer
for the base temperature is located in the mechanical housing (Figure 1, item b).
To raise the temperature in the refrigerated base:
A. P ush and hold the “set” button until 34 appears then release the “set”
button. 34 is the current set point temperature.
B. Push and release the up a rrow 2 times until 36 is d ispla yed. Push a nd
release the set” bu tton one time. The new set point, 36, will flash 3
times and then will be locked in.
To lower temperature in the refrigerated base:
A. Push and hold the set button until 34 appears and then relea se th e
“set” button. 34 is the current set point temperature.
B. Push and release the up a rrow 2 times until 32 is d ispla yed. Push a nd
release the set” bu tton one time. The new set point, 32, will flash 3
times and then will be locked in.
NOTE: It is recommended to only make changes of 2 degree increments at a
time. Allow for the unit to operate 24 hours between adjustments. If the 2
degree adjustment is not enough another adjustment can be made. The
maximum highest setting is 38 degrees and the minimum lowest setting is
28 degrees. If the settings need to go above or below this point there may be
other contributing factors as to the cause of the temperature variances,
please contact the factory at 1-800-621-8560.